Power Supplies / HLG Series /
HLG-60W series
 |
Full function adjustable waterproof power supply
Features: - Universal AC input - Built-in power factor correction - Protections:short circuit/over load/over voltage/over temp - Cooling by free air convection - OCP point adjustable through output cable or internal potentiometer - IP67/65 design for indoor or outdoor installations - Suitble for LED lighting and moving sign applications - 3 Year warranty |
|
Model |
HLG-60-12 |
HLG-60-15 |
HLG-60-24 |
HLG-60-36 |
HLG-60-48 |
|
output |
DC voltage |
12V |
15V |
24V |
36V |
48V |
|
Constant current region |
8.4~12V |
9~15V |
14.4~24V |
21.6~36V |
28.8~48V |
|
Rated current |
5A |
4A |
2.5A |
1.7A |
1.3A |
|
Rated power |
60W |
60W |
60W |
61.2W |
62.4W |
| Ripple&noise |
150mvp-p |
150mvp-p |
150mvp-p |
33~40V |
44~53V |
|
Voltage ADJ range |
11~13V |
13.5~17V |
22~27V |
200mvp-p |
240mvp-p |
| Current ADJ range |
Can be adjusted by internal potentiometer or through output cable |
| |
3~5A |
2.4~4A |
1.5~2.5A |
1~1.7A |
0.78~1.3A |
|
input |
Voltage range |
90~264VAC, 47~63HZ , 127~370VDC |
|
AC current |
0.8A/115VAC, 0.4A/230VAC |
|
Power factor |
PF>0.95/230VAC,PF>0.98/115VAC Start overload protection |
|
Efficiency |
84% |
87% |
89% |
89% |
90% |
|
Inrush current |
Cold start current 20A/115VAC, 40A/230VAC |
|
Leakage current |
< 0.5mA/240VAC |
| protection |
Over current |
95%~110% |
|
protection type :Constant current limiting, auto-recovery after fault condition is removed |
|
Short circuit |
Hiccup mode, recovers automatically after fault condition is remove |
|
Over voltage |
13.8~16V |
18~24V |
28~35V |
41~49V |
54~63V |
|
protection type:Shut down o/p voltage re-power on to recover |
|
Over temperature |
95°C±10°C(RTH2) |
|
protection type:Shut down o/p voltage re-power on to recover |
|
environment |
Working temp, humidity |
-20°C~+60, 20%~90%RH |
|
Storage temp, humidity |
-40°C~+85, 10%~95%RH non-condensing |
|
Withstand vibration |
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes |
|
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
|
fit standard |
Safety standard |
Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved |
|
eMC standard |
Fit EN55015, EN61000-3-2 ClassC(>60%load):EN61000-3-3 |
|
others |
Dimension |
174*63*39mm (L*W*H) |
|
Weight/packing |
0.75kg/20pcs/16kg/0.026m3/0.91CUFT |
|
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. |
|