Model |
HLG-100-12 |
HLG-100-20 |
HLG-100-24 |
HLG-100-36 |
HLG-100-48 |
|
output |
DC voltage |
12V |
20V |
24V |
36V |
48V |
|
Constant current region |
6~12V |
10~20V |
12~24V |
18~36V |
24~48V |
|
Rated current |
5A |
4.8A |
4A |
2.65A |
2A |
|
Rated power |
60W |
96W |
96W |
95.4W |
96W |
| Ripple&noise |
150mvp-p |
150mvp-p |
150mvp-p |
200mvp-p |
200mvp-p |
|
Voltage ADJ range |
10.8~13V |
17~22V |
22~27V |
33~40V |
43~53V |
| Current ADJ range |
Can be adjusted by internal potentiometer or through output cable |
| |
3~5A |
3~4.8A |
2.5~4A |
1.7~2.65A |
1.2~2A |
|
input |
Voltage range |
90~264VAC, 47~63HZ , 127~370VDC |
|
AC current |
1.2A/115VAC, 0.55A/230VAC |
|
Power factor |
PF>0.95/230VAC,PF>0.98/115VAC Start overload protection |
|
Efficiency |
90% |
93% |
93% |
93% |
93% |
|
Inrush current |
Cold start current 35A/115VAC, 75A/230VAC |
|
Leakage current |
< 0.75mA/240VAC |
| protection |
Over current |
95%~108% |
|
protection type :Constant current limiting, auto-recovery after fault condition is removed |
|
Short circuit |
Hiccup mode, recovers automatically after fault condition is remove |
|
Over voltage |
14~17V |
23~27V |
28~34V |
41~46V |
54~60V |
|
protection type:Shut down o/p voltage re-power on to recover |
|
Over temperature |
100°C±10°C(RTH2) |
|
protection type:Shut down o/p voltage re-power on to recover |
|
environment |
Working temp, humidity |
-20°C~+60, 20%~90%RH |
|
Storage temp, humidity |
-40°C~+85, 10%~95%RH non-condensing |
|
Withstand vibration |
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes |
|
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
|
fit standard |
Safety standard |
Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved |
|
EMC standard |
Fit EN55015, EN61000-3-2 ClassC(>60%load):EN61000-3-3 |
|
others |
Dimension |
223*69*39mm (L*W*H) |
|
Weight/packing |
1kg/20pcs/21kg/0.03m3/1.07CUFT |
|
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. |