FEATURES
1. Rated working voitage range 6,3 to 50V DC operation temperature range -40 to +105°C.
2. This series is for communication equipments, switching power supply, industrial
measuring instruments, automotive electric products, etc.
 |
CASE SIZE TABLE
| ØD |
4 |
5 |
6,3 |
8 |
| F |
1,5 |
2,0 |
2,5 |
3,5 |
| Ød |
0,45 |
| α |
(L≤7) 1 (L≥9) 1,5 |
SPECIFICATIONS
| Item |
Performance Characteristics |
| Operating Temperature Range |
-40 to +105°C |
| Rated Working Voltage Range |
6,3 to 50V |
| Nominal Capacitance Range |
0,1 to 220μF |
| Capacitance Tolerance |
±20% (120Hz, +20°C) |
| Leakage Current |
I ≤ 0,01 CV or 3μA whichever is greater measured after 2 minutes application of rated working voltage at +20°C |
| tan δ (120Hz, +20°C) |
| Working Voltage (V) |
6,3 |
10 |
16 |
25 |
35 |
50 |
| tan δ (max) |
0,24 |
0,21 |
0,18 |
0,15 |
0,13 |
0,12 |
|
| Low Temperature Characteristics |
Impedance ratio max. at 120Hz
| Working Voltage (V) |
6,3 |
10 |
16 |
25 |
35 |
50 |
| Z-25°C / Z+20°C |
4 |
2 |
2 |
2 |
2 |
2 |
| 2-40°0 / Z+20°0 |
8 |
6 |
4 |
3 |
3 |
3 |
|
| High Temperature Loading |
| Test conditions |
Post test requirements at +20°C |
| Duration: 1000 hours |
Leakage current: ≤ Initial specified value |
| Ambient temp.: +105°C |
Cap. change: within ±20% of initial measured value |
| Applied voltage: Rated DC working voltage
with rated ripple current |
tan δ: ≤ 200% of initial specified value |
|
| Shelf Life |
| Test conditions |
Post test requirements at +20°C |
| Duration: 1000 hours |
Same limits for high temperature loading. |
| Ambient temp.: +105°C |
|
| Applied voltage: (None) |
|
|
| Others |
JIS C - 5101 (IES 60384) |
STANDARD RATINGS
| Voltage (Code) |
6,3V (0J) |
10V (1A) |
16V (1C) |
| Cap, (μF) |
Code |
Case Size
ØDxL (mm) |
Ripple
Current |
Case Size
ØDxL (mm) |
Ripple
Current |
Case Size
ØDxL (mm) |
Ripple
Current |
| 10 |
106 |
|
|
|
|
4x7 |
29 |
| 22 |
226 |
4x7 |
34 |
4x7 |
34 |
4x7 |
38 |
| 33 |
336 |
4x7 |
37 |
4x7 |
40 |
5x7 |
50 |
| 47 |
476 |
4x7 |
44 |
5x7 |
50 |
5x7 |
60 |
| 100 |
107 |
5x7 |
67 |
6,3x7 |
83 |
6,3x7 |
92 |
| 220 |
227 |
6,3x7 |
112 |
8x7 |
140 |
|
|
| Maximum Allowable Ripple Current (mA rms) at 105°C 120Hz |
| Voltage (Code) |
25V (1E) |
35V (1V) |
50V (1H) |
| Cap, (μF) |
Code |
Case Size
ØDxL (mm) |
Ripple
Current |
Case Size
ØDxL (mm) |
Ripple
Current |
Case Size
ØDxL (mm) |
Ripple
Current |
| 0,1 |
104 |
|
|
|
|
4x7 |
1,0 |
| 0,22 |
224 |
|
|
|
|
4x7 |
2,3 |
| 0,33 |
334 |
|
|
|
|
4x7 |
3,5 |
| 0,47 |
474 |
|
|
|
|
4x7 |
5,0 |
| 1 |
105 |
|
|
|
|
4x7 |
10 |
| 2,2 |
225 |
|
|
|
|
4x7 |
19 |
| 3,3 |
335 |
|
|
|
|
4x7 |
24 |
| 4,7 |
475 |
|
|
4x7 |
24 |
5x7 |
29 |
| 10 |
106 |
4x7 |
29 |
5x7 |
36 |
6,3x7 |
44 |
| 22 |
226 |
5x7 |
45 |
6,3x7 |
57 |
8x7 |
65 |
| 33 |
336 |
5x7 |
55 |
6,3x7 |
62 |
|
|
| 47 |
476 |
6,3x7 |
67 |
6,3x7 |
78 |
|
|
| 100 |
107 |
6,3x7 |
95 |
8x9 |
95 |
|
|
| 220 |
227 |
8x7 |
158 |
|
|
|
|
| Maximum Allowable Ripple Current (mA rms) at 105°C 120Hz |
RIPPLE CURRENT MULTIPLIER
Frequency Coefficient (Hz)
| Cap (μF) |
50 |
120 |
300 |
1k |
10k~ |
| ≤ 47 |
0,75 |
1,00 |
1,35 |
1,57 |
2,00 |
| 68-470 |
0,80 |
1,00 |
1,23 |
1,34 |
1,50 |
|